3 General Specifications
• When using any of the PS-A’s optional devices, be sure to check
that device’s specifications for any special conditions or cautions
that may apply to its use.
• Be aware that not only does the Hard Disk have a fixed lifetime,
but that accidents can always occur. Therefore, be sure to back up
your Hard Disk’s data regularly, or prepare another Hard Disk unit
that can be used for backup.
Rated Voltage AC100V / AC240V
Voltage Supply Range AC85V to AC265V
Rated Frequency 50/60Hz
Allowable Voltage Drop
1cycle or less
(pause occurrences must be more than 1 second apart)
Power Consumption 120VA or less
Voltage Endurance
AC1500V 20mA for 1 minute
(between charging and FG terminals)
Insulation Resistance
10M or higher at DC500V
(between charging and FG terminals)
Ambient Operating Temperature
Storage Temperature
Ambient Humidity
Storage Humidity
Air Purity (Dust)
Pollution Degree
Corrosive Gases
When using
HDD
4.9m/s
2
at 10Hz to 25Hz in X, Y, Z direction
s
for 30 minutes
When NOT
using HDD
9.8m/s
2
at 10Hz to 25Hz in X, Y, Z direction
s
for 30 minutes
Noise Immunity
(Impulse Noise)
Noise Immunity
(First transient burst noise)
Electrostatic Discharge Immunity
Free of dust
Pollution Degree 2
Free of corrosive gases
+5
o
C to +50
o
C (When Using HDD)
0
o
C to +50
o
C (When NOT Using HDD)
-10
o
C to + 60
o
C
10%RH to 85%RH
(Non condensing, wet bulb temperature : 29
o
C or less)
10%RH to 85%RH
(Non condensing, wet bulb temperature : 29
o
C or less)
Noise Voltage : 1500V (via noise simulator)
Pulse Duration : 50ns, 500ns, 1
µ
s
Rise Time : 1ns
Power Line : 2kV IEC 61000-4-4
COM Port : 1kV IEC 61000-4-4
4kV IEC 61000-4-2