To enhance the PS-A's maintainability, operability and ventilation, allow
at least 50 mm clearance between the PS-A and other objects. (The
clearance must be large enough to allow you to install or uninstall op-
tion units and to attach connectors.)
Standard installation for the PS-A unit is in a vertical panel. If the PS-A
unit is to be installed in a slanted panel, the panel should not incline
more than 30° from the vertical.
If the PS-A panel is to be installed in a slanted panel that inclines more
than 30°, use forced-air cooling to ensure the ambient operation tem-
perature does not exceed 50° C.
Horizontal installation (that is, rotating the panel so that one of its sides
is the base) is not supported.
Installation Requirements
(unit: mm[in.])
50
[1.97]
50
[1.97]
Attaching the PS-A to a VESA Arm or to the Wall
To attach the unit to an Arm or to a wall, use the attachment screws to attach a
commercial-type arm or wall mount adaptor to the PS-A's rear face. (Screw hole to
screw hole width: VESA 75mm)
Please refer to each device's installation guide for installation instructions.
The VESA Arm attachment screw hole dimensions are as follows;
(unit: mm[in.])
Rear Face
Insert and tighten the four (4) M4 screws. (6mm or shorter.) The torque required for
these screws is only 0.7 to 0.8 N.m.
75[2.95]
75[2.95]
50
[1.97]
50
[1.97]
50
[1.97]
50
[1.97]
50
[1.97]