E85 Heating/Air Conditioning System
AA ccaamm mmeeaassuurreemmeenntt ((rreeffeerreennccee rruunn))
takes place the first time the control panel/control
module is operated after:
• Replacing the control panel/control module
• Replacing the cam disc
• Interruption in power supply
During this reference run, the length and distances of both cams with respect to each other
are measured and stored in the control module. A fault code is stored if cam referencing
cannot be concluded successfully after 3 attempts. In this case, adjustment of the central
kinematics for air distribution is possible only within restricted limits.
IHKS Principle of Operation
Blower
When KL15 is switched “ON”, the blower is activated in linear progression from 0 to 8 Volts
(depending on the selected blower speed). When the blower is switched “OFF” (zero posi-
tion) the IHKS is deactivated in addition to the following:
• Blower switched off
• Fresh air/recirculating air flap closed
• Mixed air flap closed (to ensure the heat exchanger does not unnecessarily heat up the
heater/air conditioner)
• Compressor switched off
NNoottee::
Rear window defogger can still be activated
Temperature Control
1. Evaporator
2. Mixed air flap
3. Heat exchanger
4. Stepper motor, mixed air flap