1 Digital Input - An alarm input for connecting devices that can toggle between an open and
closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. The device
will detect the change in digital input and transmit the signal to video surveillance servers.
Terminal Pin Define is described as below:
* Available only for device versions with enhancements
5) Audio Input / Output
The IP PoE Fixed Dome Camera supports Audio input / output with terminal block connections.
Pushing down the tab above will reveal a small slot for you to insert the end of wire. Release the
tab and the wire will be fastened by the internal spring. The connection pins are as shown in this
image:
Description
Spec
Electrically connected in parallel with the con-
nector for the power supply, this pin provides an
auxiliary connector for mains power to the unit.
This pin can also be used to power auxiliary
equipment, with a maximum current of 100mA.
Voltage: 12V DC,
Max: 1.2W
Ground
Description
Uses an open-collector NPN transistor with the
emitter connected to the GND pin. If used with an
external relay, a diode must be connected in
parallel with the load, for protection against
transient voltages.
Max load = <100mA
Max voltage = 24V
DC (to the
transistor)
Connect to GND to activate, or leave floating (or
unconnected) to deactivate.
Must not be
exposed to
voltages greater
than 30V DC.