16
The table below shows the DI/DO connection specifications:
Device
DI
Connection design TTL - compatible logic levels
Voltage
To trigger (low) Logic level 0: 0V ~ 0.4V
Normal (high) Logic level 1: 3.1V ~ 30V
Current 10mA ~ 100mA
DO
Connection design Transistor (Open Collector)
Voltage & Current < 24V DC, < 50mA
Typical Connection
Based on these specifications, if the DI device has a voltage of 0V ~ 30V or the DO device has a
voltage of < 24V (< 50mA), then the camera can supply internal power to these devices and there
is no need to connect the DI/DO device to an external power source.
Use the DIO GND and DI pins to connect a DI device and use the DIO PW and DO pins to
connect a DO device. See wiring scheme below: