Acti D21FA User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
www.acti.com
Hardware Manual
12
E23B
1) Serial Port
This port connects to serial devices via RS-485 or RS-422 protocols. Use the supplied serial
port terminal block to connect the wires from the serial device to the camera.
See How to Connect a Serial Device (for E23B only) on page 21 for connection details.
2) Ethernet Port
Connects to a network using an Ethernet cable.
3) Memory Card Slot
Insert a memory card into this slot for local recording purposes. See How to Install /
Remove the Memory Card on page 33 for more information.
NOTE: Supports microSDHC and microSDXC cards.
4) Reset Button
The purpose of reset button is to restore the factory default settings of the camera, including
administrators password.
The reset button can be used for following purposes:
1. The administrators password has been forgotten and therefore the camera cannot be
accessed.
2. In case of IP address, mask, or allow/deny filter related issues, resulting with inability to
modify these settings.
3. In case of connectivity issues or abnormal video quality.
How to do the reset?
Using a pointed object, such as a paper clip, press and hold the reset button for at least 5
seconds or until the Power LED goes off.