E-9
4 Dip Switches
The dip switches are located on the circuit board inside the PS-A unit's rear cover. For informa-
tion about removing the Rear cover, 6. Installation.
The factory settings are all OFF.
Dip
Switches
Description ON OFF
RS-232C
(COM1)
RS-232C
(COM2)
RS-422
(COM2)
RS-485
(COM2)
1
Changes #9 pin
(RI <-> +5V)
+5V 500mA external output
possible
RI
ON/OFF ON/OFF ON/OFF ON/OFF
2
Changes COM2's
communciation method
RS-422/RS-485 RS-232C
OFF OFF ON ON
3
Changes COM2 (RS-232C)
#9 pin (RI <-> +5V)
+5V 500mA external output
possible
RI
ON/OFF ON/OFF ON/OFF ON/OFF
4
Changes TX data's output
mode
TX data output is NOT
controlled via the RTS signal
TX data output is controlled
via the RTS signal. (normally
output)
OFF OFF ON/OFF ON
5
Switches the TX termination
resistance ON/OFF
Inserts termination
resistance of 220 between
TXA and TXB.
No termination
OFF OFF ON
ON/OFF
*1
6
Switches the RX termination
resistance ON/OFF
Inserts termination
resistance of 220 between
RXA and RXB.
No termination
OFF OFF ON
ON/OFF
*1
7
Switches the shorting of TXA
and RXA ON or OFF
Shorts TXA and RXA
(RS-485 mode)
No shorting
(RS-422 mode)
OFF OFF OFF ON
8
Switches the shorting of TXB
and RXB ON or OFF
Shorts TXB and RXB
(RS-485 mode)
No shorting
(RS-422 mode)
OFF OFF OFF ON
9
Changes COM2's
communciation method
RS-422/RS-485 RS-232C
OFF OFF ON ON
10 No Connection - - - - - -
<DIPSW2>
T
XD
R
TS
SW4
SW5
SW7
SW6
SW8
TXA
TXB
RXA
COM2
RXB
The COM2 compatible Serial Mode Select Switches (SW4 to SW8) operate as
shown in the circuit diagram below.
PS-A Inside
*1 If you use the termination resistance, base your settings on the connection specifications.